No objection to concept design for proposed alterations to canopy including replacement of corrugated metal roof and wood soffit on historic metal brackets; removal of light fixtures, corner stand, and railing; replacement siding at north elevation; replacement woven fabric awning with 12 inch valance; and new rooftop mechanical equipment with screens per supplemental drawings received 19 July 2016 which indicate vertical light gray metal louver screens. Proposed exterior light fixtures were not approved and were deleted from the drawings. File new submission at DCRA of working drawings, with dimensioned architectural details, with permit application for review by the Commission.
OG 16-202
OG 16-204
OG 16-216
No objection to issuance of permit for proposed alterations per supplemental drawings received 20 July 2016 which indicate retention of historic second floor joists, and rooftop mechanical equipment not visible from a public thoroughfare (per 6 July 2016 mock-up inspection) PROVIDED there are no exposed conduits or cables on exterior walls, and graphics on temporary construction are limited to 12-inch-high letters with name of business and "coming soon." Coordinate with Commission staff during construction to determine extent of historic fabric. Sign is not included in this permit application. Note: Any subsequent modifications to the approved design, including those made during DCRA technical review, must be resubmitted to the Commission for approval prior to the issuance of a permit.
OG 16-221
OG 16-236
OG 16-239
OG 16-240
OG 16-241
OG 16-248
OG 16-250
OG 16-251
No objection to issuance of permit for proposed alterations to basement fenestration, replacement of vinyl windows with 1/1 all-wood windows to fit masonry openings without fillers or secondary frame, and replacement wood doors per supplemental drawings received 15 July 2016. Proposed stone cap at parapet, which was not approved, is deleted. Historic wood windows and transoms at first floor to remain. Retain original wood brick moulds. Use half-screens only. Rooftop mechanical equipment and skylights to be not visible from a public thoroughfare. Recommend replacement of brick stair with a compatible metal stair. Note: Any subsequent modifications to the approved design, including those made during DCRA technical review, must be resubmitted to the Commission for approval prior to the issuance of a permit.
OG 16-252
OG 16-253
OG 16-254
OG 16-255
Returned without action. Submitted materials and site visit on 20 June 2016 indicate that proposed skylight would not be visible from a public thoroughfare. Refer to Historic Preservation Review Board.
OG 16-257
OG 16-258
No objection to issuance of permit for proposed 3-story frame side addition per supplemental drawings received 20 July 2016 which indicate extent of demolition is limited to lowering window sills to maintain original width of masonry openings; gable roof is located below eaves line; and metal roof matches material, color and detailing of existing roof.
OG 16-259
OG 16-260
OG 16-261
OG 16-262
OG 16-263
OG 16-264
OG 16-265
OG 16-266
No action required. See letter to Mr. Robin Morey dated 14 July 2016.
OG 16-270
No objection to issuance of permit for proposed replacement roofing, mechanical equipment with screens per supplemental drawings received 8 July 2016 which indicate equipment on roof at 1226 36th Street is relocated to lower roof, and screens have matte gray horizontal metal louvers. See OG 16-271 for demolition work. Note: Any subsequent modifications to the approved design, including those made during DCRA technical review, must be resubmitted to the Commission for approval prior to the issuance of a permit.
OG 16-271
OG 16-272
OG 16-273
OG 16-275
OG 16-278
OG 16-279
OG 16-280
OG 16-281
OG 16-282
OG 16-283
OG 16-284
OG 16-285
OG 16-289
OG 16-292
No objecting to issuance of permit for two-story rear addition and site work, including metal gates, wood pergola, and stuccoed garden walls no taller than 7'-0" per drawings received 23 June and 20 July 2016, which indicate site lighting was removed from this application. Note: Any subsequent modifications to the approved design, including those made during DCRA technical review, must be resubmitted to the Commission for approval prior to the issuance of a permit.